INDUCTIVE HEATERS
The supply units for inductive heating consist
of three-phase rectifier, middle frequency inverter, transformer and inductor.
The inverters produce AC voltage corresponding to the given technology
– melting, heating. The inductors are formed fitted to the work-piece.
The operation frequency changes from equipment to equipment, usually between
1000Hz and 20kHz. The equipment contains closed water-cooling system.
The power range is 10kW...120kW.
The equipment is manufactured for individual orders.

The type, which is produced last, is MR-30-10EB.
Technical data |
|
|
Supply voltage |
|
3x400V±10% |
- frequency |
|
50Hz±1% |
Input power |
|
45kW |
Heating frequency |
|
10kHz |
Heating power |
|
30kW |
Nominal powers |
|
10/20/50/100kW |
Measures |
|
800x800x1800mm
(without the heat exchanger and the countervailing con-tainer) |
Ambient temperature |
|
0...+35 °C |
|