COOLING SYSTEM INVERTER

The converter KL-7500 supplies the cooling system
of the railway coaches. The input voltage is the down transformed heating
voltage. It has two AC output voltages with common potential. One phase
output is for the air ventilation of the cooling system and three phases
output is for the compressor motor. The start of the last one is soft
start.
The converter consists of input rectifier, booster stage, one and three
phases inverters supplied by the intermediate DC voltage. The converter
has a microprocessor control, a data logging and measuring system which
operates as a dual digital storage oscilloscope too.
The equipment is mounted in an open frame put in the box fixed to the
under frame. The box is ventilated by the cooled air of the cooling system.
Download technical information
in PDF.

Technical data |
|
KL-7500 |
Input voltage |
|
|
-down transformed
heating voltage |
|
350V -30% +20%, 30-52Hz |
-service voltage |
|
3x400V -15% +20%, 50Hz |
-battery voltage |
|
16-32V |
Battery current
in operation/stand by |
|
300mA/1mA |
Output voltages |
|
|
-three phases
output, in start and stop mode the voltage and the frequency linear
change, run up and down time may be set, typical value 3s |
|
3x400V, 50Hz
sinus modulated square wave |
-one phase output |
|
230V±5%, 50Hz
sinus |
Nominal power |
|
|
-three phases
output |
|
7500VA |
-one phase output |
|
500VA |
Operation temperature |
|
0...+40 °C |
Volume of the
cooling air |
|
1,2m3/min |
Measures |
|
690x450x420mm |
Mass |
|
35 kg |
Protection |
|
IP00 |
|